• Ordering code: PH.EU.GSM.00

Artion

GSM Communication Module

artion

  • Back-up GSM device providing communication between the security system and a Central monitoring Station, in any case that the fixed telephony network line (PSTN) is interrupted.
  • It can also be used as the main communication means between the Alarm Control Panel and the Central monitoring Station in areas where a fixed telephony network is not available.
  • Supports all the DTMF communication formats (Contact ID, Ademco Express).
  • Option to automatically send SMS messages to up to 8 recipients only in case of total failure of communication with the Central monitoring Station.
  • Option to send to the end user (owner of the system, security officer etc) pre-programmed SMS by triggering inputs TSMS1 & TSMS2.
  • Easy to program by SMS commands from a GSM phone or through the specially designed software Artion Configuration Software from a PC. The programming of artion from a PC can be achieved either through a GSM modem connected to the PC or directly using an RS232 wired connection (in any case, a Security Code is required).
  • When high security applications require constant checking of an “ALIVE” status of the artion, we can easily and cost-free achieve this with the help of the artion Observer software.
  • Accepts SMS commands to trigger up to two different on board PGM outputs (for activating/deactivating house electronic/electric appliances or loads).
  • Option to remotely ARM/DISARM the security system by pre-programmed SMS commands, sent from the owner’s mobile cellular phone (input TSMS1 and output PGM1 must be used for this feature).
  • Two different versions (one for European countries 900/1800 MHz and one for North American countries 850/1900 MHz).
  • Globally unique IMEI number for each artion device, approved by BABT (British Approvals Board for Telecommunications).
Power Supply:
Supply Voltage 10-14 VDC
Current standby (no GSM phone call) 70 mA
Current Max (during GSM phone call) 240 mA
PGM Outputs (open collector, active low):
Max Current from “COM+” 200 mA
Max Current from external source 2 A
Max external voltage source 24 VDC
TSMS inputs (active low):
Switching Current 500 μA
Max Voltage at any time 15 VDC
Min time for pulse detection 500 mSec
Telephony related:
Max PSTN Input Voltage 80 VDC
Line Present detection threshold (line in) 10 VDC+/-20%
Line Output Voltage (on board SLIC) 37 VDC+/-10%
PSTN Off hook loop current (on board SLIC) 24 mA+/-10%
GSM Transmition Power:
Power output for GSM 900 2 Watts
Power output for GSM 1800 1 Watt
Sim card 3.3 Volts