SmartX 116 AP

Apollo Protocols 16 zones Single Loop Analogue Addressable Control Panel

SmartX 116 AP  is a single loop Analogue Addressable Fire panel based on Apollo’s S90, XP95 and Discovery protocols.

The SmartX fire panel has the following characteristics:

  • One Loop Analogue addressable panel.
  • Support for Apollo’s S90, XP95 and Discovery devices fully intermixed on same loop.
  • High current (500mA) loop driver.
  • Two analogue conventional zone inputs (on board).
  • 16 logic zones.
  • 2 Powered and monitored Siren Outputs (on board).
  • 2 generic dry contact outputs, N/O or N/C selectable by jumpers (on board).
  • 2 generic, active when grounded inputs.
  • 4 generic open collector outputs.
  • Auxiliary power connector (24V nominal, 700mA max).
  • 1 dry contact fault relay output.
  • User friendly interface: List based presentation with cursor keys navigation, filters and formatting of viewable information.
  • On screen, context intelligent short help.
  • PSTN communicator for remote reporting of events.
  • User defined descriptions for all inputs, outputs and zones.
  • LOG event registry, up to 2000 events.
  • Bypasses (disablements) for inputs and outputs.
  • Delayed outputs, Alarm verification for all inputs.
  • Day/Night operation, separate profile for each week day. Changes sensors (Discovery) sensitivity and Alarm verification.
  • Global evacuation triggered by any input, selectable at Access Level 3.
  • Periodic test reminder.
  • Walk test: An easy way to test the system by triggering one input at the time.
  • Advanced Access level control: The system is not limited to (the required by European and American) standard
  • 3 access levels: It provides 8 Access Level 2 users plus one Master user that manages the rest. There is also the Access Level 3 user (installer) and an access codes reset mechanism.
  • TCP/IP expansion port provides remote monitoring and control with optional TCP/IP module.
  • PC connectivity: The expansion port along with the required communication module permits PC connectivity for system supervision and operations.
  • Siren pattern selection for on board (switched) and loop devices (Discovery protocol).
  • Main screen branding, Installer’s contact info: The installer has one line (20 characters) on the main screen that can program to display any message he wishes (e.g. company name). Contact information (e.g. telephone number) may also be programmed into the panel for user reference.
  • Direct activation of outputs from inputs regardless of alarm/evacuation state programmed at A.L.3.
  • Group operations change specific attributes in groups of objects, making programming much more efficient.
  • Autolearn function for loop devices.
  • Manual add/remove of loop devices (easy search with Apollo’s part number).
  • Backup/Restore configuration; Save current system configuration to on-board memory and restore it if needed.
  • Real time clock/calendar with battery backup.
  • Optional eight, 24V output, monitored relay expansion module with 3A power supply and battery power backup (also fully monitored).
  • Visual overview of installed loop devices.
  • Easy device identification through their LED indicators.
  • Easy contamination levels/sensor health checks with device identification.
  • Convenient loop devices overview with alarms, faults and installed types indications.
  • Up to 15 groups of outputs for simultaneous activation (XP95 and Discovery).
  • Delayed group activation for cascaded evacuation schemes.
  • Τhe LPCB product approval does not cover the PSTN communicator facility.
  • Implements EN54-4 “Outputs to protection equipment”
  • Implements EN54-4 “Outputs to routing equipment”
  • Easy configurable inverse operation of outputs for high safety applications (e.g. fire doors).
  • Programmable activation of outputs on faults/bypasses (required for fire doors in some locales).
  • Easy identification of contaminated sensors with simultaneous LED activation on all troubled devices.
Number of loops 1
Loop current 400mA
Protocols S90, XP95 & Discovery
Fire Zones 16
Zonal indicators 16
Mains Power 220 VAC 50Hz
Conventional zones 2 (Maximum 20 detectors per zone)
Conventional zones termination resistors 4,7KOhms / 1W
Mains supply fuse 1,6A 250V
Power Supply 24 VDC / 2,5A
AUX output 24 VDC ±10% , 700mA max, current limited, monitored
Battery Backup Power 2x 12V / 7Ah sealed lead acid gel batteries
Battery health monitoring (periodic load test) Every 90 seconds
Supervised siren outputs 2 outputs, 24VDC ±10%, 1A max, fused and monitored
Generic trouble output (on main unit) non monitored Dry relay contacts NO – C – NC
Analogue Inputs 2 intern AUX pulled up inputs 1.5mA sinc current
Relay Outputs 2 general relay outputs
N/O or N/C (jumper selectable) dry contacts 28V/3A max
PGM Outputs 4 PGM outputs
Open collector, 200mA sink max current, 30V max handling
Earth faults detection and indication Front panel LCD indication & buzzer
Display 4 lines of 20 characters LCD
Enclosure Epoxy powder coated metal box
IP rating IP30
Construction 1.2mm steel sheet powder coated in grey color
Environmental Class A temperature range: -5 to 40 °C (23 to 104 °F)
Humidity: 5 to 95% RH, non condensing
Terminal blocks rating All terminals rated for 12 to18 AWG (0.75 to 2.5 sq mm)